Exercise-Ready Hard Shell Hyperbaric Chamber
64 inches deep x 100 inches long x 78 inches high | 2.0 ATA | Configurable for 1 to 4 occupants
Walk-in hard shell hyperbaric chamber rated to 2.0 ATA, measuring 64 inches deep by 100 inches long by 78 inches high and configurable for one to four occupants. Interior height allows standing, seated or light movement during a session, which is what separates this walk-in format from a lying-style chamber. Construction is 4 mm 304-grade stainless steel with a sliding glass door, dual 120 LPM compressors, and oxygen delivered at 95 percent purity or higher.
At a glance
Pressure: 2.0 ATA
Capacity: 1 to 4 occupants
Shell: 4 mm 304 stainless
Oxygen: 95 percent or higher
Noise: under 60 dB
Warranty: 3 years
Seating configurations
Single occupant
One recliner, full interior volume to a single user
Two occupants
Two airplane-style seats
Four occupants
Four bucket seats
Options
Starlight ceiling and zero-gravity seating
Oxygen and air system
- Two 120 LPM air compressors, redundant configuration
- 20 LPM high-pressure oxygen generators with integrated amplifiers
- 95 percent oxygen purity or higher
- Generated on site, no oxygen tank required
- Oil free, PSA molecular sieve
- Double inlet and outlet filtration
- Integrated air conditioning with dehumidifier
- Interior and exterior touchscreen controls
Key specifications
| HYPERBARIC PRO 64 INCH MULTIPLACE HARD SHELL CHAMBER SPECIFICATIONS | |
| Pressure rating | 2.0 ATA (15 PSI / 100 kPa) |
|---|---|
| Chamber dimensions | 64 inches deep x 100 inches long x 78 inches high |
| Chamber weight | 2,500 lbs |
| Capacity | 1 to 4 occupants, by seating configuration |
| Shell material | 4 mm 304-grade stainless steel |
| Door | Sliding glass, full height |
| Air compressors | 2 x 120 LPM |
| Oxygen generation | 20 LPM high-pressure generators with integrated amplifiers |
| Oxygen purity | 95 percent or higher |
| Controller unit | 188 lbs, 1,300 W, 67 inches long x 13 inches wide x 24 inches high |
| Voltage | 110V to 120V (220V available on request) |
| Operating noise | Under 60 dB |
| Controls | Two-way LCD display, interior and exterior touchscreens |
| Climate control | Integrated air conditioning with dehumidifier, -5 to 30 C |
| Certifications | CE, ISO9001, ISO14001, ISO13485 |
| Duty cycle | Continuous operation |
| Warranty | 3 years |
What is included
- 64-inch walk-in hard shell chamber with sliding glass door
- Integrated smart controller with redundant compressor system
- Two 120 LPM air compressors
- High-pressure oxygen generators, oil free
- Air conditioning unit with integrated dehumidifier
- Grounding system
- Two-way LCD display with interior and exterior touchscreens
- Double inlet and outlet filters with activated absorption media
- Seating in your chosen configuration
Build and materials
Shell is 4 mm 304-grade stainless steel, rated for continuous operation rather than intermittent sessions. Sliding glass door gives full-height access, so occupants walk in rather than climbing through an entry port. Interior and exterior control panels are redundant, meaning a session can be started, monitored and ended from either side, and the chamber can be run without a second person outside.
Pressurization runs on two 120 LPM compressors in a redundant configuration, so airflow continues if one unit drops. Oxygen is produced on site by PSA molecular sieve generators at 95 percent purity or higher, which removes any requirement for tank storage or refills. Air passes through double inlet and outlet filters with activated absorption media.
Operating noise stays under 60 dB through silent valve construction. Climate control is integrated rather than bolted on, combining air conditioning with a dehumidifier across a -5 to 30 C range, which matters on longer multi-occupant sessions where humidity builds. Automatic depressurization runs as a protocol on power failure. Grounding is fitted throughout for static dissipation in an oxygen-rich interior, and EMF shielding is built into the shell. Certification covers CE, ISO9001, ISO14001 and ISO13485.
Who it suits
Clinics and wellness centers
Four-seat configuration changes the economics against single-occupant chambers, since one session serves several clients. Continuous-operation rating supports back-to-back bookings through a full day.
Larger home installations
Suits a dedicated room where a household shares one chamber rather than buying several. Walk-in height means occupants sit upright, stand or stretch instead of lying flat, which works for anyone who finds a tubular chamber confining.
Space and setup requirements
Floor footprint is 100 inches by 64 inches, plus working clearance on the door side for entry and service access. Ceiling clearance needs to exceed 78 inches.
Chamber weight is 2,500 lbs, so ground floor or slab installation is the usual placement, and upper-floor installs should be checked against floor loading first.
Controller unit sits separately at 67 inches long by 13 inches wide by 24 inches high and needs its own position near the chamber. Standard supply is 110V to 120V, with 220V available on request. Confirm delivery access width along the full route to the install location before ordering.
Frequently asked questions
How many people can use this chamber at once?
Between one and four, set by the seating configuration chosen at order. Single-occupant uses one recliner, two-occupant uses airplane-style seats, and four-occupant uses bucket seats. Interior volume stays the same across all three, so a single user gets the full 64 by 100 inch footprint.
What pressure does it reach?
2.0 ATA, equal to 15 PSI or 100 kPa above sea-level pressure. Hard shell construction is what allows the 2.0 ATA rating, since soft-sided chambers are typically limited to 1.3 to 1.5 ATA.
Can you move around inside during a session?
Yes. Interior height is 78 inches and the footprint is 64 by 100 inches, so occupants can stand, stretch or move between seats rather than staying supine. Walk-in entry through the sliding glass door means no climbing in or out.
What oxygen purity does it deliver, and does it need tanks?
95 percent or higher, produced on site by PSA molecular sieve generators with integrated amplifiers. No oxygen tank, cylinder delivery or refill contract is required. Generators are oil free with double inlet and outlet filtration.
How loud is it in operation?
Under 60 dB, achieved through silent valve construction. For reference, that sits below normal conversation level, which is what makes multi-occupant sessions workable without ear protection.
What power supply does it need?
Standard configuration runs on 110V to 120V, with a 220V version available on request. Controller and compressor system draws 1,300 W. Confirm circuit capacity at the install position before delivery.
Does someone need to stay outside to operate it?
No. Controls are duplicated inside and outside on two-way LCD touchscreens, so an occupant can run a full session unassisted. Redundant control also means an attendant can monitor or end a session from outside when one is present.
What happens during a power failure?
Automatic depressurization runs as a built-in protocol, bringing the chamber back to ambient pressure without manual intervention. Compressor redundancy separately covers the case where one compressor stops while power is still available.
What certifications does it carry?
CE, ISO9001, ISO14001 and ISO13485. ISO13485 covers quality management systems for medical device manufacturing, and ISO14001 covers environmental management.
Can it run back-to-back sessions all day?
Yes, the chamber is rated for continuous operation. Integrated air conditioning and dehumidification are what make consecutive sessions practical, since interior humidity and temperature otherwise climb across a full day of use.
Warranty and support
Covered by a 3-year warranty. Support is available seven days a week for setup questions, operation and service scheduling. Replacement parts for compressors, generators, filters and seals are stocked and available separately.